Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

 
Address (UAM)Field name and typeValue range, DECPurposeWorking with the field from within an application
AutoprotectionAutoprotection
0000Program number, unsigned integer   0 - 255Ties the copy of application to the dongle for supporting several software products/UN [=[0x]…]

GrdSetFindMode,

GrdGetInfo,

GrdRead,

GrdWrite


0001Program version, unsigned integer    0 - 255Ties the copy of application to the dongle for supporting new versions of program/UV [=[0x]…]
0002Serial number, counter   0 - 65535Ties the specific copy of application to the dongle/US [=[0x]…] 
0004Bit mask, unsigned integer   0 - 65535Enables/Disables working with particular, independent modules of multimodule software/US [=[0x]…] 
0006Executions counter (Counter No.1, GP)   0 - 65535Obsolete technology, not used-

GrdSetFindMode,

GrdGetInfo,

GrdRead,

GrdWrite, 

GrdDecGP

 

0008License limit (Counter No.2), unsigned integer   0 - 65535Actual license resource of network dongles/GN2, /GN3 /GN3S

GrdSetFindMode,

GrdGetInfo,

GrdRead,

GrdWrite

 

0010Index, unsigned integer   -Serves for remote dongle programming. Not recommended for other purposes-- 

Editing general purpose fields

To edit a general purpose field, select it from the list of fields and run command Edit | press right click on mouse Field properties.

Define the new value of the field and press Apply in the dialog that will appear:

Warning

PICTURE стр 41 Image Added

The look and feel of Field properties dialog box is the same for all general purpose fields.